Transcatheter closure of patent ductus arteriosus using controlled-release coils

  • Alpay Çeliker
  • , Arman BİlgİÇ
  • , Dursun Alehan
  • , Nacİ Cevİz
  • , Mustafa Lenk
  • Hacettepe University

Araştırma sonucu: Dergiye katkıMakalebilirkişi

11 Alıntılar (Scopus)

Özet

Controlled-release coils have become available recently for the closure of patent ductus arteriosus (PDA). Transcatheter closure of patent arterial ducts was attempted in 13 patients, ranging in age from 5 months to 15 years, mean 4.1 years. Implantation of controlled-release PDA coils was attempted via the femoral artery through 5 Fr catheters in all cases except one, in whom both the femoral arterial and venous routes were used. The procedure was successful in 10 of the 13 patients. In these, the pulmonary artery systolic pressure ranged between 25 and 42 mmHg and the duct diameter varied from 1.5 to 6 mm at its narrowest point. Six of the patients received a single coil. Two coils were inserted in three patients and three coils in one patient. In three patients the ducts were too large for safe release of the coils, despite attempted implantation of up to three coils simultaneously. These coils were easily withdrawn into the catheter Immediately at the end of the procedure, the duct was completely occluded in nine of the 10 patients, and in one patient there was a small residual flow. The procedure time varied between 35 min and 2.5 h, mean 81 min and the fluoroscopy time varied from 5 to 78 min, mean 25 min. None of the patients experienced hemorrhage, diminished lower extremity pulse, hemolysis or infection. In one patient, a 5 mm coil embolized into the right pulmonary artery soon after release. It was retrieved with a snare, then 8 mm and a 5 mm coil were implanted satisfactorily in the arterial duct. At follow-up by color Doppler echocardiography, the duct was completely occluded in all patients. Transcatheter closure of patent arterial ducts by controlled-release PDA coils is effective and safe. Even when more than one coil is inserted, it is still cheaper than transcatheter umbrella closure. This method is therefore of great value, particularly in less affluent countries. 1996 Japan Pediatric Society.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)500-505
Sayfa sayısı6
DergiPediatrics International
Hacim38
Basın numarası5
DOI'lar
Yayın durumuYayınlandı - Eki 1996

Parmak izi

Transcatheter closure of patent ductus arteriosus using controlled-release coils' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Bundan alıntı yap