T1 - Rapid Analysis of Polycyclic Aromatic Hydrocarbons in Water Samples Using an Automated On-line Two-Dimensional Liquid Chromatography
AU - Armutcu, Canan
AU - Özgür, Erdoğan
AU - Karasu, Tunca
AU - Bayram, Engin
AU - Uzun, Lokman
AU - Çorman, Mehmet Emin
N1 - Publisher Copyright:
© 2019, Springer Nature Switzerland AG.
PY - 2019/10/1
Y1 - 2019/10/1
N2 - Two-dimensional HPLC (2D-HPLC) recently has received great attention due to providing high resolving power and higher peak capacities than that of 1D-HPLC, especially dealing with a wide spectrum of sample matrices containing several components. In this work, an on-line heart-cutting two-dimensional liquid chromatography (2D-LC) method was developed using monolithic columns coupled with reversed-phase liquid chromatography (RPLC). 2D-HPLC was successfully carried out using affinity-based monolithic columns at first dimension (20 cm × 4.6 mm I.D.) followed by a Pinnacle II PAH column (50 mm × 4.6 mm I.D.) at the second dimension. Furthermore, good linearity was observed for the correlation of the benzo[a]pyrene (BaP) molecule against the peak areas (R2 = 0.994) in the concentration range of 0.01–1.0 ng/mL in 30 min. The limit of detection and the limit of quantification were found to be 4.0 pg/mL and 12.0 pg/mL, respectively. Both the intra-day and inter-day precision at 0.01 and 0.1 ng/mL spiked concentrations were below than 2.35% RSD whereas the means of the recovery data of the BaP from the water samples were found to be in the range of 93.71–98.65%. These results demonstrate that the 2D-HPLC system, developed by the combination of the P(HEMA-MAPA) column and Pinnacle II PAH column, is reliable, stable, and well qualified in the extraction of polycyclic aromatic hydrocarbons from the water samples.
AB - Two-dimensional HPLC (2D-HPLC) recently has received great attention due to providing high resolving power and higher peak capacities than that of 1D-HPLC, especially dealing with a wide spectrum of sample matrices containing several components. In this work, an on-line heart-cutting two-dimensional liquid chromatography (2D-LC) method was developed using monolithic columns coupled with reversed-phase liquid chromatography (RPLC). 2D-HPLC was successfully carried out using affinity-based monolithic columns at first dimension (20 cm × 4.6 mm I.D.) followed by a Pinnacle II PAH column (50 mm × 4.6 mm I.D.) at the second dimension. Furthermore, good linearity was observed for the correlation of the benzo[a]pyrene (BaP) molecule against the peak areas (R2 = 0.994) in the concentration range of 0.01–1.0 ng/mL in 30 min. The limit of detection and the limit of quantification were found to be 4.0 pg/mL and 12.0 pg/mL, respectively. Both the intra-day and inter-day precision at 0.01 and 0.1 ng/mL spiked concentrations were below than 2.35% RSD whereas the means of the recovery data of the BaP from the water samples were found to be in the range of 93.71–98.65%. These results demonstrate that the 2D-HPLC system, developed by the combination of the P(HEMA-MAPA) column and Pinnacle II PAH column, is reliable, stable, and well qualified in the extraction of polycyclic aromatic hydrocarbons from the water samples.
KW - Two-dimensional high-performance liquid chromatography
KW - benzo[a]pyrene (BaP)
KW - monolithic column
KW - water samples
UR - https://www.scopus.com/pages/publications/85074193896
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=performanshacettepe&SrcAuth=WosAPI&KeyUT=WOS:000492941400002&DestLinkType=FullRecord&DestApp=WOS_CPL
U2 - 10.1007/s11270-019-4306-7
DO - 10.1007/s11270-019-4306-7
M3 - Article
AN - SCOPUS:85074193896
SN - 0049-6979
VL - 230
JO - Water, Air, and Soil Pollution
JF - Water, Air, and Soil Pollution
IS - 10
M1 - 249
ER -