N2 - Herein, a conjugated conducting polymer-based impedimetric aptasensor has been developed to detect beta-human chorionic gonadotropin (bHCG), the one of the important biomarkers in gynecology, from synthetic human urine samples. In this context, gold electrodes were, firstly coated with pyrrole and pyrrole-3-carboxylic acid to obtain the poly(pyrrole-pyrrole-3-carboxylic acid) [poly(Py-PyCOOH)] conductive copolymer by cyclic voltammetry (CV). Then, bHCG-specific peptide aptamer was covalently linked onto the surface via applying a well-known carbodiimide-succinimide chemistry. The sensor developed was characterized to confirm modification steps via both electrochemical methods including CV, electrochemical impedance spectroscopy (EIS), and chronoamperometry and physico-chemically via attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), atomic force microscope (AFM), and contact angle measurements (CA). The analytical performance of the sensor was evaluated in the concentration range from 1 μg/mL to 100 μg/mL for successful detection of bHCG even in the presence of interference agents. The results have also revealed that the sensor could be classified as a promising alternative to its benchmark commercial clinical methods due its superior properties such as cost-friendliness, easy-to-prepare, stable, robust, and selectivity / sensitivity.
AB - Herein, a conjugated conducting polymer-based impedimetric aptasensor has been developed to detect beta-human chorionic gonadotropin (bHCG), the one of the important biomarkers in gynecology, from synthetic human urine samples. In this context, gold electrodes were, firstly coated with pyrrole and pyrrole-3-carboxylic acid to obtain the poly(pyrrole-pyrrole-3-carboxylic acid) [poly(Py-PyCOOH)] conductive copolymer by cyclic voltammetry (CV). Then, bHCG-specific peptide aptamer was covalently linked onto the surface via applying a well-known carbodiimide-succinimide chemistry. The sensor developed was characterized to confirm modification steps via both electrochemical methods including CV, electrochemical impedance spectroscopy (EIS), and chronoamperometry and physico-chemically via attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), atomic force microscope (AFM), and contact angle measurements (CA). The analytical performance of the sensor was evaluated in the concentration range from 1 μg/mL to 100 μg/mL for successful detection of bHCG even in the presence of interference agents. The results have also revealed that the sensor could be classified as a promising alternative to its benchmark commercial clinical methods due its superior properties such as cost-friendliness, easy-to-prepare, stable, robust, and selectivity / sensitivity.
KW - Aptasensor
KW - Human chorionic gonadotropin
KW - Impedimetric detection
KW - Polypyrrole
KW - Urine
UR - https://www.scopus.com/pages/publications/85204093537
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=performanshacettepe&SrcAuth=WosAPI&KeyUT=WOS:001320215000001&DestLinkType=FullRecord&DestApp=WOS_CPL
U2 - 10.1016/j.bioelechem.2024.108820
DO - 10.1016/j.bioelechem.2024.108820
M3 - Article
C2 - 39299186
AN - SCOPUS:85204093537
SN - 1567-5394
VL - 161
JO - Bioelectrochemistry
JF - Bioelectrochemistry
M1 - 108820
ER -