Ana gezinime atla Aramaya atla Ana içeriğe atla

Heparin removal from human plasma using molecular imprinted cryogels

  • Hacettepe University

Araştırma sonucu: Dergiye katkıMakalebilirkişi

23 Alıntılar (Scopus)

Özet

In this study, heparin-imprinted poly(hydroxyethyl methacrylate- N-[(3-dimethylamino)-propyl] methacrylamide) cryogel column (HpMIP) was synthesized for removal of Hp from human plasma using molecular imprinting technique. Hp removal studies were performed from both aqueous solution and human plasma. Selectivity studies were performed using fast protein liquid chromatography (FPLC) system. The obtained results showed that the HpMIP column can remove Hp from both aqueous solutions and human plasma samples selectively. Ninety per cent of Hp was removed from 28 U/mL of human plasma samples successfully. Non-imprinted cryogel column (NIP) and plane PHEMA column were also synthesized to compare selectivity and non-specific adsorption properties.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)403-412
Sayfa sayısı10
DergiArtificial Cells, Nanomedicine and Biotechnology
Hacim43
Basın numarası6
DOI'lar
Yayın durumuYayınlandı - 2015

Parmak izi

Heparin removal from human plasma using molecular imprinted cryogels' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Bundan alıntı yap