TY - JOUR
T1 - Fast fluorometric enumeration of E. coli using passive chip
AU - Kasap, Esin Nagihan
AU - Doğan, Üzeyir
AU - Çoğun, F.
AU - Yıldırım, E.
AU - Boyacı, İsmail Hakkı
AU - Çetin, D.
AU - Suludere, Zekiye
AU - Tamer, Uğur
AU - Ertaş, Nusret
N1 - Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2019/9
Y1 - 2019/9
N2 - In this report, a passive microfluidic chip design was developed for fast and sensitive fluorometric determination of Escherichia coli (E. coli) based on sandwich immunoassay. Initially, magnetic nanoparticles (MNPs) and chitosan modified mercaptopropionic acid capped cadmium telluride (CdTe) quantum dots (QDs) were functionalized with E.coli specific antibody to form a sandwich immunoassay with the E. coli. The magnetic separation and preconcentration of the E.coli from the sample solution was performed in the vial. Conjugation of QDs to the magnetically captured E. coli and washing were performed using a passive type of microchip. The microfluidic chip consists of four microchambers connected to each other by microchannels which act as capillary valves. Signal measurement was performed at the last chamber by using a hand-held spectrofluorometer equipped with a fiber optic reflection probe. The selectivity of the method was tested with Enterobacter aerogenes (E. aerogenes) and Salmonella enteritidis (S. enteritidis), it was observed that these bacteria have no interference effect on E.coli determination. The calibration curve was found to be linear in the range of 101–105 cfu/mL with a correlation coefficient higher than 0.99. The limit of detection was calculated as 5 cfu/mL. The method was successfully applied to spiked tap and lake water samples. The results suggest that the developed method is applicable for on-site E. coli detection and offers several advantages such as large dynamic range, high sensitivity, high selectivity and short analysis time.
AB - In this report, a passive microfluidic chip design was developed for fast and sensitive fluorometric determination of Escherichia coli (E. coli) based on sandwich immunoassay. Initially, magnetic nanoparticles (MNPs) and chitosan modified mercaptopropionic acid capped cadmium telluride (CdTe) quantum dots (QDs) were functionalized with E.coli specific antibody to form a sandwich immunoassay with the E. coli. The magnetic separation and preconcentration of the E.coli from the sample solution was performed in the vial. Conjugation of QDs to the magnetically captured E. coli and washing were performed using a passive type of microchip. The microfluidic chip consists of four microchambers connected to each other by microchannels which act as capillary valves. Signal measurement was performed at the last chamber by using a hand-held spectrofluorometer equipped with a fiber optic reflection probe. The selectivity of the method was tested with Enterobacter aerogenes (E. aerogenes) and Salmonella enteritidis (S. enteritidis), it was observed that these bacteria have no interference effect on E.coli determination. The calibration curve was found to be linear in the range of 101–105 cfu/mL with a correlation coefficient higher than 0.99. The limit of detection was calculated as 5 cfu/mL. The method was successfully applied to spiked tap and lake water samples. The results suggest that the developed method is applicable for on-site E. coli detection and offers several advantages such as large dynamic range, high sensitivity, high selectivity and short analysis time.
KW - E. coli
KW - Fluorescence
KW - Immunomagnetic separation
KW - Microfluidic chip
KW - Sandwich immunoassay
UR - https://www.scopus.com/pages/publications/85070256735
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=performanshacettepe&SrcAuth=WosAPI&KeyUT=WOS:000487171800014&DestLinkType=FullRecord&DestApp=WOS_CPL
U2 - 10.1016/j.mimet.2019.105680
DO - 10.1016/j.mimet.2019.105680
M3 - Article
C2 - 31381980
AN - SCOPUS:85070256735
SN - 0167-7012
VL - 164
JO - Journal of Microbiological Methods
JF - Journal of Microbiological Methods
M1 - 105680
ER -