Özet
Fault breccias are usually not suitable for preparing smooth specimens or else the preparation of such specimens is tedious, time consuming and expensive. To develop a predictive model for the uniaxial compressive strength (UCS) of a fault breccia from electrical resistivity values obtained from the electrical impedance spectroscopy measurements, twenty-four samples of a fault breccia were tested in the laboratory. The UCS values were correlated with corresponding resistivity values and a strong correlation between them could not be found. However, a strong correlation was found for the samples having volumetric block proportion (VBP) of 25-75%. In addition, it was seen that VBP strongly correlated with resistivity. It was concluded that the UCS of the tested breccia can be estimated from resistivity for the samples having VBP of 25-75%.
| Orijinal dil | İngilizce |
|---|---|
| Sayfa (başlangıç-bitiş) | 1543-1550 |
| Sayfa sayısı | 8 |
| Dergi | Bulletin of Materials Science |
| Hacim | 37 |
| Basın numarası | 6 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - 1 Eki 2014 |