T1 - Cholesterol removal from human plasma with biologically modified cryogels
AU - Uzunoğlu, Gizem
AU - Çimen, Duygu
AU - Bereli, Nilay
AU - Çetin, Kemal
AU - Denizli, Adil
N1 - Publisher Copyright:
© 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2019/9/22
Y1 - 2019/9/22
N2 - In this study, low molecular weight heparin immobilized P(HEMA) cryogels were fabricated for the removal of LDL-C in hypercholesterolemic human plasma. After characterization studies for P(HEMA) cryogels, effects of the parameters including medium pH, CNBr concentration, heparin concentration and contact time on heparin immobilization were investigated. Blood compatibility and cell adhesion tests were also performed, and platelet and leucocyte loss for P(HEMA)-Hp cryogels were found to be 2.95% and 4.91%, respectively. Maximum adsorption capacity for LDL-C from hypercholesterolemic human plasma was found to be 26.7 mg/g for P(HEMA)-Hp cryogel while it was only 1.67 mg/g for bare P(HEMA) cryogel. The P(HEMA)-Hp cryogels exhibit high desorption ratios up to 96% after 10 adsorption-desorption cycles with no significant decrease in the adsorption capacity. The findings indicated that these reusable P(HEMA)-based cryogels proposed good alternative adsorbents for removal of LDL-C.
AB - In this study, low molecular weight heparin immobilized P(HEMA) cryogels were fabricated for the removal of LDL-C in hypercholesterolemic human plasma. After characterization studies for P(HEMA) cryogels, effects of the parameters including medium pH, CNBr concentration, heparin concentration and contact time on heparin immobilization were investigated. Blood compatibility and cell adhesion tests were also performed, and platelet and leucocyte loss for P(HEMA)-Hp cryogels were found to be 2.95% and 4.91%, respectively. Maximum adsorption capacity for LDL-C from hypercholesterolemic human plasma was found to be 26.7 mg/g for P(HEMA)-Hp cryogel while it was only 1.67 mg/g for bare P(HEMA) cryogel. The P(HEMA)-Hp cryogels exhibit high desorption ratios up to 96% after 10 adsorption-desorption cycles with no significant decrease in the adsorption capacity. The findings indicated that these reusable P(HEMA)-based cryogels proposed good alternative adsorbents for removal of LDL-C.
KW - Affinity chromatography
KW - LDL-C removal
KW - cryogel
KW - hemoperfusion
KW - heparin
UR - https://www.scopus.com/pages/publications/85067685829
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=performanshacettepe&SrcAuth=WosAPI&KeyUT=WOS:000475130700001&DestLinkType=FullRecord&DestApp=WOS_CPL
U2 - 10.1080/09205063.2019.1627652
DO - 10.1080/09205063.2019.1627652
M3 - Article
C2 - 31156065
AN - SCOPUS:85067685829
SN - 0920-5063
VL - 30
SP - 1276
EP - 1290
JO - Journal of Biomaterials Science, Polymer Edition
JF - Journal of Biomaterials Science, Polymer Edition
IS - 14
ER -