Ana gezinime atla Aramaya atla Ana içeriğe atla

Assessment of repeatability of surface electromyography signals by singular value decomposition

Araştırma sonucu: Dergiye katkıMakalebilirkişi

3 Alıntılar (Scopus)

Özet

Singular value decomposition (SVD) of full-wave rectified surface electromyography (sEMG) signals was investigated for repeatability indices of sEMG linear envelopes (LE) during biceps curl. The SVD based repeatability indices were compared with a well-known method, the variance ratio (VR). The usefulness of the offered indices was examined by a simulation and it was applied to the sEMG LEs. The results have shown that the VRs were correlated with the SVD based indices significantly. The usefulness of the offered indices on real world EMG signals practically comes from decreasing amplitudes of the first few singular values of EMG LE matrix. If repeatability is high, singular values decay fast and vice versa. If justified by further researches, the offered indices may be used practically for repeatability measurement of sEMG LEs.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)690-694
Sayfa sayısı5
DergiJournal of Electromyography and Kinesiology
Hacim18
Basın numarası4
DOI'lar
Yayın durumuYayınlandı - Ağu 2008

Parmak izi

Assessment of repeatability of surface electromyography signals by singular value decomposition' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Bundan alıntı yap