Skip to main navigation Skip to search Skip to main content

Linear accelerator-based intensity-modulated total marrow irradiation technique for treatment of hematologic malignancies: A dosimetric feasibility study

  • Mete Yeginer
  • , John C. Roeske
  • , James A. Radosevich
  • , Bulent Aydogan
  • University of Illinois at Chicago
  • Loyola University Chicago
  • The University of Chicago

Research output: Contribution to journalArticlepeer-review

37 Citations (Scopus)

Abstract

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

Original languageEnglish
Pages (from-to)1256-1265
Number of pages10
JournalInternational Journal of Radiation Oncology Biology Physics
Volume79
Issue number4
DOIs
Publication statusPublished - 15 Mar 2011
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bone marrow transplantation
  • Hematologic malignancies
  • Intensity-modulated radiotherapy
  • TBI
  • TMI
  • Total body irradiation
  • Total marrow irradiation

Fingerprint

Dive into the research topics of 'Linear accelerator-based intensity-modulated total marrow irradiation technique for treatment of hematologic malignancies: A dosimetric feasibility study'. Together they form a unique fingerprint.

Cite this