Skip to main navigation Skip to search Skip to main content

Comparison of tests for detection of methicillin-resistant Staphylococcus aureus in a clinical microbiology laboratory

  • S. Unal
  • , K. Werner
  • , P. DeGirolami
  • , F. Barsanti
  • , G. Eliopoulos
  • Beth Israel Deaconess Medical Center

Research output: Contribution to journalComment/debate

62 Citations (Scopus)

Abstract

By microdilution testing, 186 of 1,450 clinical isolates of Staphylococcus aureus were preliminarily classified as oxacillin resistant (MIC ≥ 4 μg/ml); 15 of these isolates gave conflicting results by alternative methods and were studied further. Only 2 of these (MIC > 4 μg/ml) were mecA positive; 13 were inhibited by oxacillin at 4 μg/ml. Significant numbers of S. aureus strains classified as resistant with an oxacillin MIC of 4 μg/ml may prove susceptible by other methods.

Original languageEnglish
Pages (from-to)345-347
Number of pages3
JournalAntimicrobial Agents and Chemotherapy
Volume38
Issue number2
DOIs
Publication statusPublished - 1994
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Comparison of tests for detection of methicillin-resistant Staphylococcus aureus in a clinical microbiology laboratory'. Together they form a unique fingerprint.

Cite this